thai eng






Controller

Speed Control Unit

MODEL GUA-1 GUA-2
Operation Voltage 100/110V 200/ 220/240V
Frequency 50 / 60Hz


                      

 

Characteristics

1. The unit type controller has a speed controller circuit, a condenser for the motor and the volume. 
   (Some units have to use the condenser on the outside.)
2. It is possible to control the speed of the motor when the motor and the control unit are combined with the
   exclusive connector, and AC plug cord of the accessories is contacted with single-phase 220V
   (single-phase 110V). 
3. By using an extension cable (sold separately), it is possible to control the speed to have a max distance 
   of 2.5 m between the motor and the control unit. 
4. The control range is 90~1700 rpm. 
5. The power being supplied to the Control Unit, the green LED is turned on, and the operation switch being on
   the Run side, the red LED is turned on.

 

 

MODEL GUD-1 GUD-2
Operation Voltage 100/110V 200/ 220/240V
Frequency 50 / 60Hz

 

                            

 

model GUD-1 GUD-2
Input Voltage Single-Phase100/110V, 50/60Hz±10% Single-Phase 200/220V, 50/60Hz±10%
Applied Motor
Output
6W-90W, AC SPEED CONTROL MOTOR REAL RPM
RATIO RPM
Red 7 Segment 4 Digit after red LED on
Red 7 segment 4 Digit after green LED on
Applied Motor
Current
2.0A
Indication 
of LED
Power Supplied (STOP) = Green LED        Running(RUN) = Red LED
Case of Error = Red LED blinks                Soft Up movement = Red, Soft Down movement = Red
T.G selection = Red                                 DATA LOCK = Red
Control Method

AC phase control method according
to digital PID operation by Micom 
Sensor Type

Sensor Type AG, TG(Tacho), 
contact switch, encoder

12~24 poles TG or 
12~24 Pulse 1KHz 
per a revolution
Control Type speed control in proportion to
measurement value 
(PID operation automatic control by
Micom)
Speed Volume
Method
each 1.5, 10, 50, 100 increases, 
decreases depending on setting input
Control Extent 50Hz=90~1400rpm, 60Hz=90~1700rpm
Control Extent Micom magnetic diagnosis Consuming
Electricity
about 5W(10AV) Motor 
except for consuming electricity
Control Error average± 0.5% 4 Setting Keys RUN/STOP, MODE, UP, DOWN
Measurement Method pulse period operation 
measurement method by Micom
Remote 
RUN/STOP
Remote S/W
STOP/RUN control type within 0~10sec Inner Vibration
Durability
10~55Hz2, 0.7mm X, Y, Z directions 2 hours
Voltage in
Insulation
sufficient to withstand 1500V at 
50/60Hz applied between the electric
terminal and the ground for over 1 min.
Inner Shock Durability 250m/sec 6 directions 3 times
Inner Noise electricity line 1500V/ms
TG line 200V/ms
Controller Lifetime Semi-permanent 
if ambient is most suitable
Insulation
Resistance
between TG terminal and the
ground for over 1 min.
DIMENSION 60(W)×100(H)×103(D)
Ambient
Temperature
-10